My pump seems to trip the GFCI breaker each time it is plugged in. The problem lies, where the power dies could be the breaker, time clock, outlet or at the terminal board. Now when my sweeper comes on my waterfall feature from my spa does not turn off like it should and my sweeper moves slowly and in circles. You dont need a seal plate kit you can just use the shaft seal SPX1600Z2. If plumbed backwards into the PUMP and RETURN ports, it would exhibit these symptoms. I appreciate your knowledge. Today,I cut the pipe off where the water leak was coming from and repaired it. Anything else to fiddle with or bad motor? Now when it is turned on it works for a few seconds then stops pumping and makes a humming sound. Shaft seals may blow out if a valve after the pump is turned or briefly closed while the pump is running. Took out filters and it pumps perfect. I was hoping that you can give me some advice. It is so poorly designed and the helper handle is basically useless because it bumps into the outlet flow tube and the jandy. Also they winterized the place where the water circulates inside the pool and it wont unscrew so we can let some of the water out and put the original piece back on. I set up to measure motor current, using 100amp, 100mv shunt, the current draw is 6.5 amps @241V (Pump pressure about 17-18 psi) "thumbnailUrl": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
Do I need to use lube on the gasket, how much sand should be in the filter? On page 30 of the Aquarite troubleshooting guide, it goes into depth about troubleshooting that rectifier. Hi Tiffany, in most inground pool cases, the pool pump should be powered by a breaker on the home main panel, which powers a breaker on the pool equipment pad sub-panel breaker box. This is the round cylinder in the back of the motor, at 9 oclock. And 93, thats just the temp of the water, the flames are much hotter of course, thats what is melting the plastic. To reset your average salt level, turn the unit to OFF and then back to AUTO. When I turned off the pump I saw that it spit a little bit of water out of a Jandy Valve. If you had a multiport valve, you could put it on recirculate and verify, but since perflex have no such valve, the only other test would be to actually plumb around the filter, by installing a bypass valve and line, or just temporarily routing plumbing around the filter, to bypass the filter completely. Thanks. Articles and resources for swimming pool owners and DIYers. Put it in the line at the pool, and as the pump begins to catch prime, crimp the hose and slowly pull out of the pipe. Its concerning to suddenly hear strange sounds coming from your Hayward pool pump. Tonight, I tried to manually start the filter and all I hear is a click in the mother board. Just push the red button back in. I have a Hayward pump making more of a rattling sound inconsistent in nature. Had it running today at high rpm and totally turned off after about 20 minutes. What do you think is the problem? Perflex filters can also leak out of the bump handle, this fix usually involves replacing the shaft o-rings. Also look for loose wires or corrosion (stored next to chlorine tabs during winter?) When it shuts down, does the High Salt light come on? Should I shut down my system until I can get this fixed or is it safe for the motor to continue operation? See below for more detail. Its running now but when I turn it off it wont restart. Hi Leah, good question, and I understand. By morning all the dead algae filters back into the pool and it take about 4 days to clear. If you have a multiport valve, set it on Recirculate, to bypass the filter, and rule out any problems there. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
1. If not the skimmer being blocked, then its an air leak BEFORE the pump impeller. After reinstalling, give it the full charge of DE powder, plus a little extra. If the meter reads zero, and stays at zero the capacitor is bad. Hi Chuong, the Leslies RS750CA is the same as the Hayward Super II pump, which are $500-$600. could that be a GFCI tripping? Please advise. When iturned it back on, it ran for a few seconds, sounded funny, then shut off. Sanitization, Learn About If the shaft does spin fine, and is not locked up, you can try a new capacitor, or check your current cap, with an ohmmeter. Its a Hayward pump. put on high speed. There is water under the motor not sure from where. I just purchased a pool home that is utilizing a Hayward Northstar SP4020NS I have noticed that when the pump shuts off water briefly blows out of the strainer cover, like a pressure release. Do you have to find the pump up with water before turning it on? If the switch does not close after the blower starts the control will go into lockout with the blower running. This error can result commonly in springtime, after the pump has sat all winter rust can develop between the stator and rotor. any ideas? Cleaners will remove the grease/oils, and acid will remove scale deposits. Please help. If your pump has an open bracket (where you can see the motor shaft), you can grab the shaft with your fingers or straight pliers, to break any rust. "mainEntityOfPage": "https://blog.intheswim.com/hayward-pool-heater-troubleshooting/",
If not, I would suspect voltage issues, especially with the overheating, be sure pump is wired to accept the incoming voltage (115V or 230V), and it doesnt fluctuate more than 10%, +/- . Air leaks can occur over time, the most often areas are a loose pump lid, unlubed pump lid oring, or my favorite, the loose threaded fitting that brings water into the pump. Press and hold the diagnostic button for 3 to 5 seconds. Here is the manual: Now, it could also be rust inside the motor, natural when a pump sits for long periods of time, in a non-climate controlled location. Only thing I can think of, is the Key assy aligned properly when it was screwed back onto the valve body? What do you suggest? Hi Joe, the Perflex DE filter has a few dozen flex tubes covered in a mesh fabric. Hayward Blue Essence Troubleshooting, everything works well but the circulation is half as strong as my last pump.Tried everything,BACKWASH,checked for air leaks. Zeolite Market Share In 2022 | Top Players [ Shanghai Hengye, Zeotech Corp, Blue Pacific Minerals (BPM), UOP (Honeywell) ] In-Depth Analysis, Forecast to 2027 with Top Countries Data | A Answered on 5/26/2022 by InyoPools Product Specialist Craig C.. Hello J. Camfrog Pro Extreme Atau Gold - Camfrog Indonesia. There are ants around the AutoChlor, the lights come on but which is the problem, the pump or the switching system? ), 2) the pump lid o-ring (is it lubed? Seems like filter is dirty , so I bumped it several times (once with motor on to really force water through) that usually does it. Sparking can also come directly from a short in the windings of the motor. Hi, Good day everyone. Double check that connections are snug and fitted properly. Hi Ernesto, hmmm, Im not quite sure, but sounds like it could be either low voltage, or a loose connection, or something mis-wired between the terminal board and the capacitor? But, that may not be it, if you say the shaft is getting stuck each time? For a better experience, please enable JavaScript in your browser before proceeding. If I shut the pump off for a little while and put it back on it repeats the same thing over and over, strong at first for about 5 minutes then weak. Terrible storms 2 nights ago. Capacitors are cheap to replace, order the exact MFD number, printed on it, or you can pick up local at a motor shop. 1. If the salt level is within range, go to Step 3. Make sure you. "width": "611",
Hi Donna, the screws that are removed to rotate are the long thru-bolts that run thru the motor, and are turned at the rear of the motor (spray with WD-40 first). Hi Carolyn, yes either the thermostat or other temp sensor, if present, would be responsible for that symptom. Our unit comes on for about 15 secs. A check valve could also be a solution, but a Drain King is different, they are used to pressure lines, for blowing out clogged drains usually, but also useful to pressurize the suction manifold to look for air leaks, or for priming a pump that has issues catching prime. Hi Jack, according to the manual, the Drive Error Pump is Stalled error usually refers to water or moisture on the circuit board, under the display panel. 5 Changed the seal Hi, I have a Hayward pump and it was running my barracuda g3 just fine but it stopped hours later. There must be a leak. I just replaced the flow switch and that solved one problem, but now I'm only able to produce chlorine when the system is on Super Chlorinate. My pump motor does not start until I spin the shaft then it runs for about 15 min and shuts off and I can hear the motor humming and it feels very hot to the touch. Hi Sean, the Powerflo pump lid has a very tight seal, likely the o-ring needs to be removed, cleaned off with a rag, replaced and lubed with a Teflon lubricant like Magic lube or other Pool Lube. External bypass is out of adjustment. Could be insects or the copper arms are bent, or something caught up in the works, This is usually directly in the center of the motor a centrifugal switch, steel with side springs, and a triangular shaped switch attached at 6 oclock, but contacting the cent. I shut it down again before the problem got worse. Either the pump lid oring is missing, or the lid (cover) is not tight, or a loose threaded pipe coming into the pump, or leaky valves (skimmer, main drain) air leaks are always in front of the pump. Just installed a replacement Super Pump and realized a point that may help others as they install. Hi there, I have a 2-speed (hi and low) Hayward pump. of and to in a is " for on that ) ( with was as it by be : 's are at this from you or i an he have ' not - which his will has but we they all their were can ; one also the dr myers ultrasound. We were cleaning our pool filter one day and went to restart the pump and it didnt. 25 LibriVox About. Hi John, that is going to be either a cavitation noise, where the pump is starved for water, or if this noise is new, it would likely be the front and/or rear motor shaft bearings wearing out. Or you can buy the bearings and seal, and with a set of bearing pullers you can replace your own. I have a hayward sp2610x15 1.5hp pump that I got in May 2017. Hi Martha, open the air bleeder, perhaps there is a lot of air in the tank, drawn in by the pump. Then we hear a click and the whole display goes blank. I disconnected it and plugged the Aquatrol in alone; that worked fine. I completely back washed and clean the system two times making sure the filter was put together properly and there were no holes in either the manifold or the filter grids. Could also be a loose wire connection, the power wires. It makes humming sound 1-2 times before starting. Next year, June 21, 2021, is the date that VS (Variable Speed) pumps will be required, over 1-hp in size. Is there something on the board I need to change? Hi Shannon, well thats encouraging. If the motor makes no noise at all, not even a peep, then its usually a power issue. Like it is locked up. Repair or replace any tripped breakers or blown fuses. Check the motor vent holes, (bottom front) to be sure they are not clogged. My pump impeller does not budge. Now it runs nice and quiet but still overheats and shuts off. After about 15minutes the pump stopped and the motor was super hot. of and in " a to was is ) ( for as on by he with 's that at from his it an were are which this also be has or : had first one their its new after but who not they have 25 The following steps will provide a guide on how to recalibrate a Hayward Aqua Rite. If no power there, check the timer, if no power there, check the breaker, if no power there Is the main breaker in the house on? Products, View Hi, my above ground pool pump will run when not attached to the pool and there is no water in it, but when I get it hooked up to the pool and let the hoses and pump fill, it no longer turns on. What do you think? On traditional intermatic time clocks, you also have to make sure the timer dogs are tight, or they can slip, use pliers to tighten the nut tighter to avoid. Hello, we have a 2 speed Hayward Tgistar pump it just stopped running, I have east the breakers both at the controller and on the main panel, the pump is hot to the touch and will restart after about two minutes then shutdown again. If thats not the problem, then it could be that you replaced the motor with a full rated motor, but the impeller (and old motor) was an uprated motor, or vice-versa. Hi Doug, could be a bad breaker, or bad wiring between the pump and breaker. New motors are always set to accept 230V when shipped, but can fall out of adjustment, or if you are using 115V, then the motor (if reversible voltage motor), the motor can be switched to accept 115V. ), or 4) loose suction side valves, I have a hayward 1081 century with 3/4 hp motor with top mounted capacitor. Also the pool breakers are loose now. "primaryImageOfPage": {
Is there something I forgot to do? Why would this suddenly happen? "height": "219",
Ive checked all my hoses for clogs and skimmer and pump baskets are clean. If you have power coming into the motor, but no pump noise, check (Power off) that wire connections are tight, and inspect the wire for breaks or damage. I believe I checked everything and hoping its just the electric cord and the fact that it is corroded and loose and likely loosing electric current after it gets heated up a bit. Not sure what type of sweeper you have, but other adjustments can sometimes be made to prevent circling, but often it is a low flow issue. Hi! Slo puedes comparar 4 propiedades, cualquier nueva propiedad aadida reemplazar a la primera de la comparacin. Hi Mike, pumps are too hot to touch normally, running at 140 or so. It is a H400FDN series. While it is normal for an appliance plug to become warm, it is abnormal for such a plug to get hot. i hope this helps, but I am also maybe missing something. my hayward filter assembly on top leaks at the seam between the top (held on by six bolts) and the bottom. 99% of the time its no problem 1% of the time something could burst, usually a plumbing fitting, a bad glue joint or clamped fitting. Turned it off tho clear the skimmer basket.. water level is correct. There is not much that can be done to increase flow rates for a smaller pump, with exception to reducing plumbing restrictions with larger pipe size and less elbows, etc. On your filter (X-Stream and Voyager) there are two large wing nuts under the lid which secure the pressure gauge and air bleeder. The article says: Hi Shannon, assuming that your pump is single speed (not dual speed or variable speed), it runs at a constant 3450 RPM, and is not possible to run at a lower speed. Thoughts? They are easily replaceable. Drain plugs, pump lid, pipe coming into pump, skimmer or main drain valves, low water level, stuck skimmer weir, or the dreaded underground cracks in pipe (rare problem). Specialties: Cycling, Kickboxing, The Twelfth Edition of Business Research Methods reflects a thoughtful revision of a market standard. Do you have any idea what I need to do to remedy the problem. When the pressure rises 7-9 psi above the clean, start-up pressure, that indicates that its time to backwash or clean the filter. The hub was leaking and had to be replaced. Replumb your flow switch if it does not meet the distance requirements. What can I do? Is it rigid PVC or flexible pipe? bought a SP2610x152s super pool pump 1.5 hp. Hi Dave, the square gasket for the lid, can sometimes come out of the groove on a Superpump, Id check that first, and make sure the lid is very tight. Pump cavitation produces a lower pitched gravely sound, caused by the pump being starved for water from closed valves or clogged lines or clogged impeller. Could be the pump lid, drain plug, or the pipe that threads into the pump. They just reopened my pool. If that doesnt solve the problem, then work through the steps below. Thanks! Troubleshooting Guides; Troubleshooting Guides. Then check the GFCI for loose wires. If you attached the cord, make sure that the wires are correctly attached to the terminal board, and the ground wire secure. Almost like it was revving. the , . outlet still on. runs normal on 110 but does not make any sound when set on 230 and wired accordingly. So yes it could be the filter, very clogged and in need of a deep cleaning, but probably not a filter mechanical issue. Mine just did the same. Or you may have an Air Leak in front of the pump, on the pump lid or the pipe coming into the pump usually. Hi Davy, my pump is on a timer and will occasionally fail to turn on in the morning. Pumps can also leak water from the shaft seal, which can appear to be a housing/seal plate leak, but will leak only directly from the bottom. Please note: The majority of our literature and brochures are in English only. Could have been an outlet problem too, make sure wires or terminals arent touching anything except each other. Good luck! If the bolts do not tighten fully, it could be that the housing threaded receivers are loose and spinning as you try to tighten the bolts. Normally though, it takes more like 15 minutes before the pump is cool enough to turn back on again, at which point you may hear a click, as the overload resets, just a second before the pump turns on again. Overheating pumps are usually DOA, in my experience, but there may be hope. If the pump runs without water for very long it will burn up the shaft seal, and if run for hours and days, can literally melt the pump, sometimes even catch fire (rarely), even with a small amount of water in it. The low speed works fine. It is plugged into a gfi outlet. If the wiring is Ok and the error persists, replace the sensor. If it is a 15amp breaker, but the pump wants 9amps and the aquatrol wants 7 amps, (for example, made-up numbers) thats a total of 16amps, too much. dual-speed pool pump. My wear ring fits very loosely and it seems like impeller shaft has worn down. Any ideas on what may be going on? This occurred after a lengthy power outage. Replaced motor and seal on my Hayward Northstar. Third guess is closed or broken valves, clogged filter, clogged impeller, or other obstruction preventing water flow. Try to spin the impeller by hand, to be sure that the motor shaft spins freely and is not bound-up. "@type": "BlogPosting",
Now what? Before you test your capacitor, take note of its appearance. Put your power leads on both sides of the transformer, should be 115V IN, and 28V OUT, (or close to those numbers). I dont want to over tighten it. Hose it off well, and inspect the tubes for any holes, and if found, replace them with new. It need not be a fancy $100 meter, it can be a $10 meter from Radio Shack. Hi when you say it shuts down, I assume you mean that the water stops flowing? Hayward has a 4 year warranty on these drives. "url": "https://blog.intheswim.com/"
I have a Hayward pump with DE filter. After doing some reading, I now understand that the IG pump shouldnt be used with the AG pool and weve been doing the wrong thing for almost 30 years. 1. Use a flashlight, and you should see gears moving thru the small view hole. "keywords": "",
Spray some ant killer around, and replace the capacitor, but first, check all connections, maybe check incoming power (to the motor) if you have a test meter. Yes this pool was install without GFCI protection, (of course we will installing an equipment ground and GFCI Breakers.) Not too bad of a repair, if you want to attempt yourself. 4. leaky valve or unions in front of pump Remove and replace the two seal halves, in the same orientation as removed, spring half slides over impeller stem, donut half is pushed into seal plate. Was working fine until I backwashed and cleaned the basket by the pump. I have a Hayward H250, when I turn it on the green heat light is lit and the heater seems to make a howling sound. Is the GFCI test button tripped? PUMP IS 15 YEARS OLD. If the No Flow LED is flashing, wait 60 seconds after starting your pump and filter. I also suspect a bad pressure gauge, if flow is nearly non-existant, pressure should be very low. No lubricant is needed for spider gaskets. I changed the sand and it is still occurring. I have a D.E. "height": "219",
4. inspect capacitor, usually mounted at 9 oclock, for signs of leaking, bulging, cracking What can I do? I have an aboveground kayak saltwater system . Ive checked out your blog and you had very good info for audience. Professional Profile, View All You might be surprised by how many people neglect to check this area. Power is getting to the pump but the pump will not run?. Will it do it any harm if we leave it running? Or very high mineral content (very hard water), or oily substances. Look closely for any visible damage in the rear of the motor, anything loose, disconnected, chewed, melted, broken, burnt or cracked. My 4 year old pump is working well so I am not looking to switch it, but I am curious if I should consider raising its location to above pool water level. HELP!!! On high it seems fine. Follow disassembly/assembly procedures (pages 32 -37). If the blower prover switch opens unexpectedly during operation the control will shut down and attempt to re-light. For the leaking underneath, that sounds like the shaft seal SPX1600Z2 or it could be leaking around the plumbing fitting threads, where water exits the pump, and is running down the side of the pump and dripping off the bottom. Clean Gasket (no bits of debris or de powder), 2. Please help. Everything seems to be set up correctly on the filter and motor. I backwashed and started again and it was good for another 24 hours and the circulation stopped again and the pressure reached max. Pressing on/off buttom followed only by click sound of switch. Could be a short in the wiring that could be tested with an Ohm meter, for resistance. We just verified all our time settings. Indeed, it was the capacitor and as soon as I replaced it ($6) the pump is working like a champ. Water Features, View All What should I do? The motor has all of the same specifications of the Hayward motor that is being replaced, what could possibly cause the motor not ot work? What could be wring? Flow switches require a minimum flow fate of 11 gallons per minute to stay consistently closed, Water temperature is below 50 degrees F. (The cell output scales back to 20% once it reaches 60 degrees F and shuts off at 50 degrees F.). Thanks again! Air could also be entering the pump from the threaded pipe or union that is attached to the inlet port, which may also spray or drip when the pump shuts off. If control input data is corrupts, the heater will shut down and lockout. Remove the back of the motor and look for anything loose wires, switches, tabs. The other rectifier is rated as 18-33 VDC. Thanks. Tried to vacuum. On Jandy valves, the spurt may be from the lid, or from the center of the lid around the stem, from a broken or missing grease cap (grey valves), or from a crack/damage. Just started getting a No Flow error. 2. 2 year warranty. Second most common air leak on a Super Pump would be the incoming pipe fitting. Suggestions on what to do next. Our Hayward pump is leaking and we just added our opening chemicals. If the motor was submerged, it may not recover. It could also be a loose switch in the back of the motor. All For some time now I have been pushing along with my old cell (t-9 model). Try again? If you download the owners manual on the Ecostar there is some further information about Drive Errors, and some things you can try, in the troubleshooting section, to verify the fault, and also lists the part number for the drive, if needed. IF so, replace the fitting, or pack pool putty or silicone around the fitting, and leave it running for 24 hours, until the sealant sets up hard. When I turn on the pump, it sucks water through but only 2/3 of basket is filled as if a suction leak. UNK the , . When I installed the filter and pump the water in the filter came gushing out of the filter and the top mount was raised up even though the clamps were tightly screwed in place. I checked the breaker and plug connection and they were fine. Lots of things to check, but its either air entering the system, or an obstruction, both on the suction side of the pump, or before the impeller. Before purchasing the new pump, I replaced the breaker just to be safe, but it is still throwing the new one. I flipped on the breaker and the pump made this god awfully loud noise, immediately flipped it off. Gas pressure is ok. Any ideas? I hope new filters fix the problem!!! If theres no power at the switch/timer, go back further to the breaker. thanks. Pump is grounded. Hi Davy, Please consider. Pump making loud grinding noise, any solutions. Do you feel my capacitor is going bad or my motor? They do not seem to have enough stooch even though they are rated at 1HP like my original motor. Do I need to clean filter? Attached please find a copy of the Aqua Plus Operation Manual Please note Section - Configuration Menu Items, Cell Type Selection, page 16. I will re-check all the wiring. Davy, You can check the visual motor check (if you have an intermatic clock), to see if the motor gears are turning, which means the timeclock motor is good and the power from the breaker is good. I have an older Haywood super pump 3/4 hp, i replaced it with a new 3/4 hp motor. Probably not related to the water, but something is not right. Most above ground pool pumps are not self-priming, and mot inground pumps are self-priming. Additionally, ensure all o-rings, valves, and gaskets are lubricated and situated in the right positions. Free, Pool Equipment Parts: Make your Own Repairs, https://www.intheswim.com/p/hayward-super-pump-pool-pump-motor-1-5-hp-threaded-shaft, https://www.intheswim.com/p/hayward-super-pump-shaft-seal-assembly-spx1600z2, http://waterheatertimer.org/How-to-wire-Hayward-two-speed-pump.html, https://hayward-pool-assets.com/assets/documents/pools/pdf/manuals/super-pump-vs-S2603VSP.pdf?fromCDN=true, https://www.intheswim.com/c/filter-parts?pcode=208&scode=SOCIBLOG, https://www.totallyhayward.com/techservices/attachments/Serial%20Number%20Read%20REVISED%201-2012.pdf, https://www.intheswim.com/images/PDFs/E1964-Manual.pdf, https://hayward-pool-assets.com/assets/documents/pools/pdf/manuals/tristar-vs-S3202VSP.pdf?fromCDN=true, https://www.intheswim.com/c/pump-parts?pcode=208&scode=SOCIBLOG, https://www.intheswim.com/p/hayward-spring-seal-w-seat-spx1250xz2c. Check the incoming motor voltage to be sure it is correct, too low or too high can cause problems. Also check that no wires are touching any metal, and check for any bare/scraped wires. The pump shuts off because it trips the circuit breaker in the house. My pump just quit working, figured it was old so I replaced the motor. Check all the wire connections inside the motor on the terminal board, the 2 wires and the ground wire. No air leaks and it only does this as the heater warms the water up during hot days. Juat replaced motor. Check all connections, circuit breakers, and fuses. But first, remove the fingers again, and soak the entire Nest Assembly in a bucket filled with pool filter cleaner, to dissolve oils and scale. Copyright 2022 In The Swim. put in a new motor and had the old motor repaired. 3. slide pump backwards, out of the housing, remove diffuser and wear ring from impeller